Search results for " crystalline"

showing 10 items of 152 documents

Thermal Analysis, Mechanical and Rheological Behaviour of Melt Manufactured Polyethylene/Liquid Crystal Polymer Blends

2011

Modification of properties of conventional thermoplastics with thermotropic liquid crystal polymers, from one hand, allows decrease their viscosities, substantially facilitating processing conditions, and, from another hand, allows increase their exploitation properties. Orientation of the labile structure of liquid crystal polymer in extrusion or injection moulding causes specific reinforcement (so-called self-reinforcement) to occur in the blends containing liquid crystal polymer. Up to now the effect of self-reinforcement is mostly investigated in the blends, containing considerable amount of liquid crystal polymer. In this research the effect of minor amounts of liquid crystalline co-po…

chemistry.chemical_classificationpolyethylenelcsh:TN1-997Hydroxybenzoic acidMaterials scienceThermoplasticthermotropic liquid crystalline polymersynthesisPolymerPolyethyleneThermotropic crystalchemistry.chemical_compoundrheological propertieschemistryLiquid crystalUltimate tensile strengthGeneral Materials ScienceInjection mouldingstructuremechanicalComposite materiallcsh:Mining engineering. MetallurgyMedžiagotyra
researchProduct

Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.

2011

Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…

Materials sciencegenetic structuresUltraviolet Raysmedicine.medical_treatmentIntraocular lensRadiationmedicine.disease_causelaw.inventionOpticsRadiation ProtectionlawLens CrystallinemedicineAnimalsHumansIrradiationLenses Intraocularbusiness.industryMediterranean RegionAlbedoeye diseasesLens (optics)OphthalmologyWavelengthmedicine.anatomical_structureSunlightHuman eyesense organsRabbitsbusinessUltravioletJournal francais d'ophtalmologie
researchProduct

Synthesis of PP-LCP graft copolymers and their compatibilizing activity for PP/LCP blends

1998

The aim of this work was the synthesis of new graft copolymers consisting of polypropylene (PP) backbones and liquid crystalline polymer (LCP) branches, to be used as compatibilizing agents for PP/LCP blends. The PP-g-LCP copolymers have been prepared by polycondensation of the monomers of a semiflexible liquid crystalline polyester (SBH 1 : 1 : 2), that is, sebacic acid (S), 4,4′-dihydroxybiphenyl (B), and 4-hydroxybenzoic acid (H) in the mole ratio of 1 : 1 : 2, carried out in the presence of appropriate amounts of a commercial acrylic-acid-functionalized polypropylene (PPAA). The polycondensation products, referred to as COPP50 and COPP70, having a calculated PPAA concentration of 50 and…

PolypropyleneMaterials scienceCondensation polymerPolymers and PlasticsSebacic acidCopolymersGeneral ChemistryCompatibilizationFunctionalized polypropyleneSurfaces Coatings and FilmsPolypropylene-LCP blendsPolyesterchemistry.chemical_compoundDifferential scanning calorimetryLiquid crystalline polymer (LCP)chemistryTacticityPolymer chemistryMaterials ChemistryCopolymerCompatibilization
researchProduct

Growth of large liquid crystalline domains of phospholipids at air-water interfaces

1990

Abstract The fusion of condensed phase domains in a fluid environment in monolayers is studied. A system of electrodes permits the non-invasive and predetermined movement of single domains while the film is observed by fluorescence microscopy. Two domains fuse when they are brought into contact with special positions of their borderlines. The experiment yields information about the molecular structure of the domains and allows us to fabricate very large domains. The equilibrium size is estimated and verified.

Fusionbusiness.industryLiquid crystallineChemistryMetals and AlloysSurfaces and InterfacesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsOpticsChemical physicsLiquid crystalPhase (matter)MonolayerElectrodeMaterials ChemistryMoleculeAir waterbusinessThin Solid Films
researchProduct

Polymers with Side-chain Mesogenic Units

1989

Liquid crystalline (LC) polymers are usually prepared by combining formanisotropic structural units (so-called mesogenic groups) and polymer chains (Figure 1). The mesogenic groups used for this purpose are rigid rod-like or disc-like units, which are known to favour LC phases in the case of low molar mass substances. There are two main ways of combining the mesogenic groups and polymer chains. The mesogenic groups can either be incorporated actually into the polymer chains (LC main-chain polymers, see Volume 5, Chapter 38) or they can be attached to flexible polymer chains as side groups (LC side-chain polymers).

chemistry.chemical_classificationMolar massMaterials sciencechemistryLiquid crystallineMesogenPolymer chemistrySide chainPolymer
researchProduct

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT

2021

Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…

Adultmedicine.medical_specialtyBiometryAnterior ChamberSignificant negative correlationPositive correlationSwept-source Fourier domainCorrelationLens thicknessOphthalmologyLens CrystallineHumansMedicineOptical coherence tomographybusiness.industrySpur-to-spurReproducibility of ResultsMean ageAxial lengthWhite-to-whiteMiddle AgedClinical routineCrystalline lens riseAxial Length Eyemedicine.anatomical_structureLens (anatomy)Original ArticlebusinessTomography Optical CoherenceOptometryJournal of Optometry
researchProduct

1985

Etude des phases isotrope, nematique et smectique de melanges de polymeres protones et en partie deuteries

chemistry.chemical_classificationCrystallographyDeuteriumChemistryLiquid crystallineLiquid crystalPolymerNeutron scatteringDie Makromolekulare Chemie, Rapid Communications
researchProduct

Crystalline subtype of pre-descemetic corneal dystrophy.

2014

Purpose: To report corneal findings in a familial case of the crystalline subtype of pre- Descemetic corneal dystrophy. Case Report: A 19-year-old girl and her 44-year-old mother were found to have asymptomatic, bilateral, punctiform and multi-colored crystalline opacities across the whole posterior layer of the corneas. Endothelial specular microscopy revealed the presence of white round flecks located at different levels anterior to the endothelium. No systemic abnormalities or medications could be related to account for these findings. Conclusion: To the best of our knowledge, this is the third familial report of this rare corneal disorder. Differential diagnosis may include Schnyder cor…

Crystalline Subtype Pre-Descemetic Corneal Dystrophylcsh:Ophthalmologygenetic structureslcsh:RE1-994Crystalline Corneal Deposition Specular MicroscopyCase ReportCrystalline Subtype Pre-Descemetic Corneal Dystrophy; Crystalline Corneal Deposition Specular Microscopysense organseye diseases
researchProduct